Item |
Content |
Replacing intervals(hours) |
Remark |
|||||
500 |
1000 |
1500 |
2000 |
4000 |
8000 |
|||
Element of Air Filter |
Clean external dusts |
* |
|
|
|
|
|
Prolong or shorten replacing interval according to dust volume |
Replace element of filter |
|
|
|
* |
|
|
||
Specialied coolant |
Quality coolant |
*1st |
|
|
|
*+ |
|
sample once every week,check oil.replace when necessary |
Super coolant |
|
|
|
|
*1st |
*++ |
||
Suction Valve |
Check |
|
|
|
|
* |
|
replace when need |
Oil Filter |
Replace new filter |
*1st |
|
|
* |
|
|
|
Oil-air Separator |
Replace new separator |
|
|
|
|
* |
|
|
MIN. Pressure Valve |
Check opening pressure |
|
|
|
|
* |
|
|
De-Dust Cooler |
Clean external dusts |
* |
|
|
|
|
|
Air cooled. Prolong or shorten according to the working condition |
Descale Cooler |
Clean internal scale |
|
|
* |
|
|
|
Water cooled. Prolong or shorten according to the working condition |
Safety Valve |
check sensitive or not |
|
|
|
|
|
* |
|
Soneloid valve |
Check |
|
* |
|
|
|
|
|
Pressure gauge |
check |
|
|
* |
|
|
|
|
Drain Valve |
Check whether blocked |
|
* |
|
|
|
|
|
Condensate drain |
discharge condensate in oil tank |
* |
|
|
|
|
|
Replace according to wear-out condition |
Motor |
Fill lubricating condensate |
|
|
|
|
* |
|
refer to guideline of motor |
Electric |
check main connection and poles |
* |
|
|
|
|
|
1st check should be done after 150 hours service |
Belt |
check and adjust |
|
|
* |
|
|
|
1st check should be done after 150 hours service |